The battery in use is different due to the working conditions, and often has insufficient charging (especially short-distance vehicles). Supplementary charging should be made when the following cases: 1 The specific gravity of the electrolyte drops below 1.200; 2 winter discharges more than 25%; 3 summer discharges more than 50%; 4 lights are dim; 5 start weakness. Supplementary charging is done in two phases. The first stage is charged at a current of the rated capacity of 1/10, and the single voltage is 2.4V, and the electrolyte begins to discharge the bubble, generally take 10 to 11h. In the second phase, the current is reduced until sufficient, it is generally 3 to 5 hours. If the electrolytic solution is not intended, it should be adjusted, and the method is the same as the initial charge. Recommend: LiFePO4 Battery Manufacturer Energy storage battery Manufacturer Integrated machine energy storage battery series Manufacturer Lead lithium battery Manufacturer Outdoor Backup Battery Manufacturer Portable outdoor power supply Manufacturer Power battery Manufacturer Powerwall LiFePO4 Battery Manufacturer Battery rack Manufacturers Telecom LiFePO4 Battery Manufacturer Wall mounted battery storage Manufacturer China Lifepo4 Battery