Geerady Lifepo4 Battery Manufacturer is a professional supplier of lithium-ion batteries and power solutions.

Email:sales@geerady.com



Maintenance and maintenance knowledge of a pile of boom batteries

Maintenance and maintenance knowledge of a pile of boom batteries1. The discharge capacity of the bunch of booms is represented by a 5H rate, and its capacity varies with discharge conditions (discharge current, battery temperature, electrolyte density). That is, the discharge current is large, the time is short; the discharge current is small, long use time.

2, avoid overplay, overcharge; over-discharge means that the cell voltage is below 1.7V; the electrolytic solution density is less than 1.14g / cm3, it is difficult to return to the optimal state by charging. Overcharge, refers to charging to a monomer battery voltage above 2.6V; the electrolyte density reaches 1.28 g / cm3, and it is still allowed to continue charging for 2 to 3 hours. Then the electrolyte is too high, and the electrode plate, the separator aging. Overcharge, over-discharge will shorten the battery life.

3, when charging, be sure to open the battery pack, save a good ventilation environment, if the electrolytic liquid temperature exceeds 55 ¡ã C, it must be suspended, or reduce charging current.

4, strictly prohibit fireworks and placed metal products on the battery; the battery will produce explosive hydrogen, if placed metal products will cause short-circuit failures, generating sparks, and hydrogen can cause explosion, must stay away from fire.

5. Keep the high-end battery surface cleaning, battery charge, and discharge, there is a small amount of residual liquid on the battery cover, resulting in a micro-short circuit, making the battery usage time and lower charging efficiency. Wastewater enters the inside of the battery when cleaning the surface of the battery.

6, the electrolyte density, the density of the electrolyte decreases during discharge, rising during charging, the electrolyte will naturally decrease in use, then refill pure water to maintain a predetermined liquid level height (do not add dilute sulfuric acid) Only the same density dilute sulfuric acid can be added to the electrolyte overflow, and the debris enters the inside of the battery.

7, the electrolyte density, the density of the electrolyte decreases at the time of discharge, rising during charging, the electrolyte will naturally decrease in use, then refill pure water to maintain a predetermined liquid level height (do not add dilute sulfuric acid) Only the same density dilute sulfuric acid can be added to the electrolyte overflow, and the debris enters the inside of the battery.

8, prevent the electrode plate vulcanization, the battery is used and stored, which produces a plate vulcanization. After the plate is vulcanized, its capacity will decrease, and the battery pack should be normalized for each 20 days in the case of deactivation. A balanced charging is performed every month in normal use to eliminate the uniformity of the monomer battery in the whole group. It is not allowed to charge the battery after the battery is used  Recommend: LiFePO4 Battery Manufacturer Energy storage battery Manufacturer Integrated machine energy storage battery series Manufacturer Lead lithium battery Manufacturer Outdoor Backup Battery Manufacturer Portable outdoor power supply Manufacturer Power battery Manufacturer Powerwall LiFePO4 Battery Manufacturer Battery rack Manufacturers Telecom LiFePO4 Battery Manufacturer Wall mounted battery storage Manufacturer China Lifepo4 Battery