When ensuring greater elasticity, organizations regularly maintain the uninterruptible power supply (UPS) that provides power supply guarantees. The maintenance is intended to minimize risks and operate the UPS in a safe and efficient manner. However, if the active behavior itself constitutes a risk? What kind of response measures can I take?
For example, a data center of a British airline is faulty in 2017 due to human mistakes. And the human error is the main reason for the problem in the UPS maintenance process, and the engineer may press the wrong switch, or execute the program in the wrong order.
Although it is easy to accuse the engineer's negligence in these cases, this error is usually caused by the operation procedure is not standardized, the identification is poor, or even the training measures are not in place. You can avoid risks by eliminating these problems at the beginning of the UPS installation.
For example, if the installed UPS system is a power supply system consisting of large parallel UPS and complex switches, a chain device should be added in the design. These measures have caused users to switch in a controlled and safe way, but they are often excluded from the design to save costs.
Equipment monitoring throughout the day also provides powerful protection, which should be part of the organization maintenance system. Strict training is also critical.
Easy measures can also be used. By real-time update basic labels and switching schematic can avoid disaster occurrence. It is recommended that organizations provide a document record for clear switching programs. If the on-site maintenance is very critical, the maintenance personnel will be reminded when the maintenance personnel will be reminded (two engineers check the executive before performing each action) will prevent most people from being errors.
Advanced technology
Any maintenance and maintenance may bring risks for UPS or switch devices, so it needs to reduce the number of repairs. Most problems (including the failure of electrical components) can be detected in advance by monitoring the heat of the electrical components.
For example, if the connection point of the electrical component is not tightened, it will start warming and finally invalid in some way. Check the most effective solution for each connection is to adopt thermal imaging techniques. Thermal imaging technology identifies a potential problem.
Monitoring equipment and capabilities
All-weather equipment monitoring also provides powerful protection and should become part of organizational maintenance measures. Strict training is also crucial, while ensuring that the engineers of the equipment can be competent.
Organizational maintenance staff should not be afraid to ask the maintenance service provider, and they have a qualified certificate, which is related to the organization itself and its engineers, and always needs to check on-site treatment.
Powerful maintenance measures should also ensure a timely and efficient response when the UPS fails. Service level protocol needs to apply to the key to the application. If you can access UPS only within a normal operation time, such maintenance contract is meaningless for all-weather responses to UPS. That is, if the data center is operating all day, and the service is critical to the business, then the 24-day response is required.
Organization needs to explain the composition of the response, which may be just a telephone number or an engineer that is dealt with on-site, and needs to review the qualifications and level of engineers.
Review of the current UPS maintenance procedures will help determine and reduce the risk of key operations that have not been expected before tissue. Organizations can avoid accidents by performing due diligence.
Recommend:
LiFePO4 Battery Manufacturer
Energy storage battery Manufacturer
Integrated machine energy storage battery series Manufacturer
Lead lithium battery Manufacturer
Outdoor Backup Battery Manufacturer
Portable outdoor power supply Manufacturer
Power battery Manufacturer
Powerwall LiFePO4 Battery Manufacturer
Battery rack Manufacturers
Telecom LiFePO4 Battery Manufacturer
Wall mounted battery storage Manufacturer
China Lifepo4 Battery